OPTIMUS integrates public address, voice alarm, and industrial intercom systems at the Salamanca Combined Cycle Power Plant in Mexico.

The company has supplied a solution based on its COMPACT system and J&R industrial intercom equipment for one of the main power generation facilities operated by Mexico's Federal Electricity Commission (CFE), with an installed capacity of 927.10 MW.

 

The Salamanca Combined Cycle Power Plant, located in the Mexican state of Guanajuato, has incorporated an integrated public address, voice alarm, and industrial intercom solution from OPTIMUS. The installation enables the management of operational communications and emergency announcements at an energy facility that supplies electricity to more than 500,000 households, as well as industries and businesses across west-central Mexico.

 

With an installed capacity of 927.10 MW and an operating efficiency of 60%, the plant is one of the major power generation facilities operated by the Federal Electricity Commission (CFE). It combines natural gas and steam turbines to maximise the energy extracted from the fuel through two generation processes.

 

Communication and safety in a demanding industrial environment

The characteristics of a combined cycle power plant present significant challenges for communication systems. Turbine and generator rooms have high ambient noise levels, while certain natural gas handling areas require equipment suitable for operation in potentially explosive atmospheres.

These conditions are compounded by the distribution of operational areas throughout the plant, making rapid communication between technical personnel and the control room essential.

To meet these requirements, OPTIMUS has supplied a solution that integrates public address, voice alarm, and industrial intercom systems over an IP network architecture, facilitating centralised monitoring and communication management.

 

COMPACT system delivering nearly 4,000 W RMS

At the heart of the installation is OPTIMUS's COMPACT public address and voice alarm system, based on an IF-7P4ETH/0 main controller and 12 IF-7W250ETH distributed amplification units, each delivering 250 W RMS and featuring Ethernet connectivity.

The configuration incorporates MP-250WD1 and MP-120WD1 power modules, bringing the total output power to nearly 4,000 W RMS.

This architecture enables public address messages to be distributed across the plant's different zones, with continuous monitoring of loudspeaker lines and amplifiers.

The system also supports the management of voice evacuation procedures from the control room, either centrally or through its connection to the fire detection system.

A DC-700ETH console has been installed to control announcements, allowing operators to select broadcast zones and activate preprogrammed procedures.

The sound distribution system is completed by 40 A-256BTM loudspeakers, 40 AC-850T units, and BS-60BA equipment for specific areas of the installation. This combination allows sound coverage and sound pressure levels to be adapted to the conditions of the various operational and technical spaces.

 

SIP intercoms with IP66 and IK10 protection

Communication between plant personnel and the control room is provided by 19 J&R JR101-6B-H-SIP industrial intercoms, designed to operate in demanding environments.

These devices feature IP66 protection against dust and water, IK10 impact resistance, a protective front door, a telephone handset, and native SIP connectivity.

Each intercom incorporates six programmable buttons that enable direct calls to predefined destinations, such as the control room, maintenance, or security, without the need to dial numbers.

This functionality facilitates communication in situations requiring an immediate response, while the front cover protects the keypad and handset against the accumulation of dirt and dust.

The installation also includes JR-TP-02 complementary accessories.

 

An integrated IP network architecture

One of the project's key features is the integration of the three communication systems into a common architecture, with OPTIMUS acting as the single technical point of contact.

This solution simplifies the network infrastructure, eliminates the need for parallel communication systems, and centralises monitoring and diagnostic tasks.

Compatibility between the different devices is addressed from the installation's design stage, facilitating system coordination and subsequent maintenance work.

 

OPTIMUS strengthens its presence in Mexico's energy sector

 

The Salamanca Combined Cycle Power Plant is part of Mexico's strategic power generation projects. CFE is also planning a second unit at the same site, Salamanca II, with an additional capacity of 478 MW and an investment of more than $400 million. It is scheduled to begin operations in 2028.

 

OPTIMUS's involvement in Salamanca follows its equipment supply for the Villa de Reyes Combined Cycle Power Plant in San Luis Potosí in November 2025.

Follow OPTIMUS

FacebookFacebook LinkedInLinkedIn XX YouTubeYouTube

You may also be interested